Duct Leakage Testing in Lee MA

Duct Leakage Testing in Lee, MA — CFM25 Limits & Test Process (2026)

The Lee duct-tightness requirement, how the Duct Blaster test works, the CFM25 thresholds you must meet, and how to schedule a documented test.

Lee codeBase
Leakage limit≤ 4 CFM25/100 ft²
TestRequired*
StandardRESNET / ASTM
✓ RESNET-Certified HERS RatersServing all 351 MA Cities & Towns★ 5.0 · 1,823 reviewsFree Quote — No Obligation
Lee, Massachusetts home undergoing a duct leakage test
Residential duct leakage testing in Lee, MA.

Duct Testing Quick Facts — Lee

  • Ducts must leak no more than 4 CFM25 per 100 sq ft of conditioned floor area.
  • Testing is required when any duct runs outside conditioned space (attic, crawlspace, garage).
  • Systems entirely within the thermal envelope may be exempt — we confirm before testing.
  • Performed with a calibrated Duct Blaster and documented for your building department.

Why Duct Leakage Matters in Lee

Leaky ducts waste the energy your heating and cooling equipment produces — pushing conditioned air into attics and crawlspaces instead of living space. Massachusetts code limits that loss to 4 CFM25 per 100 square feet of conditioned floor area (measured at 25 pascals). Sealed ducts lower bills, improve comfort, and are required to pass the Lee energy code and complete a HERS rating.

Lee Duct Leakage Limits

Test timingMaximum leakageApplies when
Rough-in (air handler installed)≤ 4 CFM25 / 100 ft²Ducts outside conditioned space
Post-construction (final)≤ 4 CFM25 / 100 ft²Standard verification point
Ducts fully inside envelopeTesting may be waivedAll ducts in conditioned space

Lee follows the base energy code, and the 2021 IECC applies this same duct-tightness limit to new systems.

How the Duct Blaster Test Works

1. Seal Registers

  • Cover supply/return grilles
  • Connect Duct Blaster to system

2. Pressurize to 25 Pa

  • Fan pressurizes ductwork
  • Measure leakage (CFM25)

3. Compare & Document

  • Normalize per 100 ft²
  • Pass/fail vs 4 CFM25
  • Signed report

Schedule Duct Testing in Lee

We perform certified duct leakage testing throughout Lee, typically alongside your blower door test and HERS rating. See the full Lee energy code requirements for how it all fits together.

Quick Answers — Lee Duct Testing

Is duct leakage testing required in Lee?
Yes, whenever ductwork runs outside conditioned space (attic, crawlspace, or garage) in a new Lee home.
What is the duct leakage limit in Lee?
No more than 4 CFM25 per 100 sq ft of conditioned floor area.
When is duct testing waived in Lee?
If all ducts and the air handler are inside the thermal envelope, testing may not be required.
How is duct leakage measured?
With a calibrated Duct Blaster that pressurizes the ducts to 25 pascals and measures leakage (CFM25).
5.0
★★★★★
1,823 verified 5-star reviews across Massachusetts
“Duct leakage test done same week — documented and passed for Lee.”— Verified Review
“Clear CFM25 results and practical sealing advice. Highly recommend.”— Verified Review
“Reliable duct testing for our Lee projects, every time.”— Verified Review

Schedule duct testing in Lee.

Talk to a certified Massachusetts HERS rater and get a free, no-obligation quote.

Call (617) 571-4368 Get a Free Quote

HERS Rating Specialist, we are dedicated to providing top-tier energy consulting services to homebuilders, architects, developers, and contractors across Massachusetts.

© 2026, All Rights Reserved.

Get In Touch

You have been successfully Subscribed! Ops! Something went wrong, please try again.