Duct Leakage Testing in North Andover, MA — CFM25 Limits & Test Process (2026)

The North Andover duct-tightness requirement, how the Duct Blaster test works, the CFM25 thresholds you must meet, and how to schedule a documented test.

North Andover codeStretch
Leakage limit≤ 4 CFM25/100 ft²
TestRequired*
StandardRESNET / ASTM
✓ RESNET-Certified HERS RatersServing all 351 MA Cities & Towns★ 5.0 · 1,823 reviewsFree Quote — No Obligation
North Andover, Massachusetts home undergoing a duct leakage test
Residential duct leakage testing in North Andover, MA.

Duct Testing Quick Facts — North Andover

  • Ducts must leak no more than 4 CFM25 per 100 sq ft of conditioned floor area.
  • Testing is required when any duct runs outside conditioned space (attic, crawlspace, garage).
  • Systems entirely within the thermal envelope may be exempt — we confirm before testing.
  • Performed with a calibrated Duct Blaster and documented for your building department.

Why Duct Leakage Matters in North Andover

Leaky ducts waste the energy your heating and cooling equipment produces — pushing conditioned air into attics and crawlspaces instead of living space. Massachusetts code limits that loss to 4 CFM25 per 100 square feet of conditioned floor area (measured at 25 pascals). Sealed ducts lower bills, improve comfort, and are required to pass the North Andover energy code and complete a HERS rating.

North Andover Duct Leakage Limits

Test timingMaximum leakageApplies when
Rough-in (air handler installed)≤ 4 CFM25 / 100 ft²Ducts outside conditioned space
Post-construction (final)≤ 4 CFM25 / 100 ft²Standard verification point
Ducts fully inside envelopeTesting may be waivedAll ducts in conditioned space

This threshold is enforced under the Stretch Code that applies in North Andover.

How the Duct Blaster Test Works

1. Seal Registers

  • Cover supply/return grilles
  • Connect Duct Blaster to system

2. Pressurize to 25 Pa

  • Fan pressurizes ductwork
  • Measure leakage (CFM25)

3. Compare & Document

  • Normalize per 100 ft²
  • Pass/fail vs 4 CFM25
  • Signed report

Schedule Duct Testing in North Andover

We perform certified duct leakage testing throughout North Andover, typically alongside your blower door test and HERS rating. See the full North Andover energy code requirements for how it all fits together.

Quick Answers — North Andover Duct Testing

Is duct leakage testing required in North Andover?
Yes, whenever ductwork runs outside conditioned space (attic, crawlspace, or garage) in a new North Andover home.
What is the duct leakage limit in North Andover?
No more than 4 CFM25 per 100 sq ft of conditioned floor area.
When is duct testing waived in North Andover?
If all ducts and the air handler are inside the thermal envelope, testing may not be required.
How is duct leakage measured?
With a calibrated Duct Blaster that pressurizes the ducts to 25 pascals and measures leakage (CFM25).
5.0
★★★★★
1,823 verified 5-star reviews across Massachusetts
“Duct leakage test done same week — documented and passed for North Andover.”— Verified Review
“Clear CFM25 results and practical sealing advice. Highly recommend.”— Verified Review
“Reliable duct testing for our North Andover projects, every time.”— Verified Review

Schedule duct testing in North Andover.

Talk to a certified Massachusetts HERS rater and get a free, no-obligation quote.