180 Franklin St Framingham, MA

01702 United States

Duct Leakage Testing in Falmouth MA

Duct Leakage Testing in Falmouth, MA — CFM25 Limits & Test Process (2026)

The Falmouth duct-tightness requirement, how the Duct Blaster test works, the CFM25 thresholds you must meet, and how to schedule a documented test.

Falmouth codeStretch
Leakage limit≤ 4 CFM25/100 ft²
TestRequired*
StandardRESNET / ASTM
✓ RESNET-Certified HERS RatersServing all 351 MA Cities & Towns★ 5.0 · 1,823 reviewsFree Quote — No Obligation
Falmouth, Massachusetts home undergoing a duct leakage test
Residential duct leakage testing in Falmouth, MA.

Duct Testing Quick Facts — Falmouth

  • Ducts must leak no more than 4 CFM25 per 100 sq ft of conditioned floor area.
  • Testing is required when any duct runs outside conditioned space (attic, crawlspace, garage).
  • Systems entirely within the thermal envelope may be exempt — we confirm before testing.
  • Performed with a calibrated Duct Blaster and documented for your building department.

Why Duct Leakage Matters in Falmouth

Leaky ducts waste the energy your heating and cooling equipment produces — pushing conditioned air into attics and crawlspaces instead of living space. Massachusetts code limits that loss to 4 CFM25 per 100 square feet of conditioned floor area (measured at 25 pascals). Sealed ducts lower bills, improve comfort, and are required to pass the Falmouth energy code and complete a HERS rating.

Falmouth Duct Leakage Limits

Test timingMaximum leakageApplies when
Rough-in (air handler installed)≤ 4 CFM25 / 100 ft²Ducts outside conditioned space
Post-construction (final)≤ 4 CFM25 / 100 ft²Standard verification point
Ducts fully inside envelopeTesting may be waivedAll ducts in conditioned space

This threshold is enforced under the Stretch Code that applies in Falmouth.

How the Duct Blaster Test Works

1. Seal Registers

  • Cover supply/return grilles
  • Connect Duct Blaster to system

2. Pressurize to 25 Pa

  • Fan pressurizes ductwork
  • Measure leakage (CFM25)

3. Compare & Document

  • Normalize per 100 ft²
  • Pass/fail vs 4 CFM25
  • Signed report

Schedule Duct Testing in Falmouth

We perform certified duct leakage testing throughout Falmouth, typically alongside your blower door test and HERS rating. See the full Falmouth energy code requirements for how it all fits together.

Quick Answers — Falmouth Duct Testing

Is duct leakage testing required in Falmouth?
Yes, whenever ductwork runs outside conditioned space (attic, crawlspace, or garage) in a new Falmouth home.
What is the duct leakage limit in Falmouth?
No more than 4 CFM25 per 100 sq ft of conditioned floor area.
When is duct testing waived in Falmouth?
If all ducts and the air handler are inside the thermal envelope, testing may not be required.
How is duct leakage measured?
With a calibrated Duct Blaster that pressurizes the ducts to 25 pascals and measures leakage (CFM25).
5.0
★★★★★
1,823 verified 5-star reviews across Massachusetts
“Duct leakage test done same week — documented and passed for Falmouth.”— Verified Review
“Clear CFM25 results and practical sealing advice. Highly recommend.”— Verified Review
“Reliable duct testing for our Falmouth projects, every time.”— Verified Review

Schedule duct testing in Falmouth.

Talk to a certified Massachusetts HERS rater and get a free, no-obligation quote.

Call (617) 571-4368 Get a Free Quote

HERS Rating Specialist, we are dedicated to providing top-tier energy consulting services to homebuilders, architects, developers, and contractors across Massachusetts.

© 2026, All Rights Reserved.

Get In Touch

You have been successfully Subscribed! Ops! Something went wrong, please try again.